Direct answer: When a printhead fails electrically, the fire board (or firing section of the carriage board) that drove it may have been damaged in the same event, or may have caused the failure in the first place. If a new head is fitted to that damaged channel without testing, the faulty amplifier can deliver excessive, distorted or unstable voltage and destroy the new head within minutes, hours or days. The same can happen through a burnt head cable that carries the short forward. The rule is simple: after any electrical head failure, find out why the head failed and have the firing channel, head cables, settings and power supply checked before fitting a new head. The cost of these checks is small compared with the price of an i3200 or XP600 head.
Checking for a bad fire board before fitting a new head is the cheapest insurance a print shop can buy.

Table of Contents
This is one of the most expensive patterns in eco-solvent printer service: a head fails, a new one is fitted, and the new one fails too. Sometimes a third head follows. Each time the head supplier is blamed, but the real cause sits upstream. This article explains how it happens, how to recognise the risk, and what to check before risking another head. It is part of our fire board series; for background, read what is a fire board.
How heads normally die versus how they die electrically
Printheads fail in two broad ways, and the difference matters for what you do next.
| Failure type | Typical causes | Typical pattern | Risk to the next head |
|---|---|---|---|
| Mechanical or ink-related wear | Clogging, dried ink, air ingestion, nozzle plate damage, head strikes, long idle periods, incompatible ink | Gradual nozzle loss, deflection, missing nozzles that partly recover with cleaning | Low from the electronics; fix the ink or maintenance cause |
| Electrical failure | Short circuit, overvoltage, wrong cable insertion, ink in connector, firing circuit fault, surge | Sudden total loss of a head or large block of nozzles, burnt smell, heat, damaged connector | High if the firing channel or cable is damaged |
When the failure is clearly gradual and ink-related, the electronics are less likely to be involved. When the failure is sudden and total, or comes with burning signs, assume the electronics may be damaged until proven otherwise.
How a bad fire board damages a head
The firing circuit amplifies a low-level waveform into the drive voltage the head needs. Its output stage uses power transistors that switch rapidly. Several failure modes can harm a head:
Shorted output transistor
If an output transistor fails short, the drive line may sit at a supply voltage instead of following the waveform. The head’s piezo elements and internal switching chips can be exposed to continuous or excessive voltage, causing overheating and failure of the head’s electronics or piezo elements.
Distorted or unstable waveform
A partially failed amplifier, a failing capacitor or an unstable supply can produce a waveform with spikes, ringing or wrong timing. The head may still fire, but with stress on the piezo elements and switching chips. Damage may build up over hours or days, so the head seems fine at first and then fails.
Excessive amplitude
A fault in the circuit that sets amplitude, or a corrupted setting, can drive the head at higher voltage than intended. Overdriven heads run hot and age quickly. Our article on head voltage settings explains why this matters.
Missing protection
Firing circuits often include protective components. If these have already been damaged by a previous short, the circuit may no longer limit current properly, so the next fault does more damage.
How a shorted head damages the fire board
The damage also runs the other way. A head that develops an internal short, for example from ink entering its electronics, from a head strike, or from a manufacturing defect, can draw excessive current from the firing channel. The output transistors and related components may be overloaded and fail. Sometimes they fail completely, so the channel stops working. Sometimes they are weakened, so the channel still works but now produces a distorted output or has lost its protection. A weakened channel is the most dangerous outcome, because it looks fine until a new head is connected.
The cable in the middle
Head cables connect the firing channel to the head. When a short occurs, the cable contacts may be burnt, leaving carbon tracks or melted plastic that create a new short path. If that cable is reused, it can damage a new head and a new board even if both are perfect. This is why technicians replace head cables after any electrical failure. Our article on head cable vs carriage board fault finding explains what burnt cables look like.
The repeat-failure cycle
Put together, the pattern looks like this:
- A head fails, perhaps because of an ink leak into its connector, or because the firing channel had a developing fault.
- The short damages the firing channel and burns the head cable contacts.
- A new head is fitted using the same cable on the same channel, without checks.
- The damaged channel or cable destroys the new head, sometimes immediately, sometimes after a few days.
- The supplier is blamed for a bad head. Another head is ordered.
- The cycle repeats until someone checks the electronics.
Each turn of the cycle can cost a head worth tens of thousands of rupees, plus downtime. Breaking the cycle requires checking the electronics before the new head goes on.
An illustrative scenario: three heads in one month
The following scenario is a composite of the kind of case service teams see regularly. A shop runs a double-head i3200 eco-solvent printer. During a rushed manual cleaning, cleaning fluid drips near the head 2 connector. The next morning head 2 is not detected. The operator orders a new head, fits it using the existing cable, and enters the voltage value. The head works for two days, then loses a large block of nozzles and stops firing.
The supplier is called and says the head shows signs of electrical damage, so the warranty is refused. A second new head is fitted, again with the same cable. It fails within hours. Only then is a technician called. The technician finds burnt contacts on the head 2 cable, residue on the board connector, and a damaged output stage on the head 2 firing channel. The board channel is repaired, the cables are replaced, the connector is cleaned, and a third head is fitted. It has run normally since.
The total cost was three heads, a board repair, cables and about a week of reduced production. If the electronics had been checked after the first failure, the shop would have needed one head, one board repair and a set of cables. The lesson is that the second head should never have gone on before the channel and cable were checked.
Warning signs that the electronics may be involved
- The old head failed suddenly and completely, rather than gradually.
- There was a burning smell, visible smoke, or heat around the carriage.
- The head cable contacts or head connector show discoloration or burn marks.
- The failure happened right after a head change, cable work, cleaning or a leak.
- The failure followed a power cut, storm, voltage fluctuation or electrical work in the building.
- Previous heads have failed on the same channel.
- The board shows visible damage or runs unusually hot.
If any of these apply, treat the firing channel as suspect.
What to check before fitting a new head
The following checks should be carried out by a trained technician. Owners can use the list to make sure nothing is skipped.
| Check | Purpose |
|---|---|
| Investigate the old head’s failure: sudden or gradual, any burning, what happened before | Decide whether electronics are suspect |
| Inspect old head connector and cable contacts | Burns indicate a short that may have damaged the channel |
| Replace head cables and adapter boards involved | Remove a common carrier of damage |
| Inspect the board for burns, swollen capacitors, cracked components, residue | Identify visible damage |
| Check firing section supply voltages | Confirm the circuit is powered correctly |
| Test output transistors and related components for shorts (power off) | Detect failed output stage |
| Observe drive waveform with suitable equipment, without the new head connected | Confirm correct shape and amplitude |
| Compare channels on multi-head boards | Spot a channel that differs from the healthy one |
| Verify head type and voltage settings | Avoid overdriving the new head |
| Check for ink leaks and fix the source | Prevent a repeat short |
| Check power supply stability and earthing | Rule out surges and sagging supply |
Not every workshop has an oscilloscope for waveform checks. In that case, substitution with a known-good board can be used, but only after confirming the head is not shorted, so that a faulty head does not damage the replacement board.
Testing the old head safely
If there is doubt about whether the old head or the electronics failed first, a technician may examine the old head. Visual inspection of the connector, checks for internal shorts using appropriate methods, and the failure history give clues. A head with a clear internal short is a likely origin of the problem, but it may still have damaged the channel on its way out. A head without signs of internal damage that failed suddenly raises suspicion of the firing circuit or cable.
Never test a suspect head by plugging it into a good board “to see if it works”. If the head is shorted, it can damage the good board. Never test a suspect board by connecting an expensive new head. Use proper test methods or low-risk substitution.
Why replacement head warranties often do not cover this
Head suppliers usually test heads before sale and examine returned heads. A head that failed because of overvoltage, a short from the board, a damaged cable or ink in the connector typically shows signs that the supplier will identify as external damage. Such failures are usually excluded from warranty. This means that if a faulty firing channel kills a new head, the cost is generally yours. Checking the electronics first is the only reliable protection. Our article on printhead warranty conditions explains typical exclusions.
The cost comparison
Consider the economics. Checking a firing channel, replacing head cables and confirming settings typically costs a technician visit and a few small parts. A new i3200 or XP600 head costs many times more. If there is even a modest chance that the channel is damaged, the checks pay for themselves.
| Approach | Upfront cost | Risk |
|---|---|---|
| Fit new head immediately, reuse cables, no checks | Head only | High risk of losing the new head if electronics are damaged |
| Replace cables, check settings, fit head | Head plus cables | Medium; channel damage still undetected |
| Full check: cables, board inspection, supply, output, settings, leaks | Head plus cables plus technician time | Low; most causes identified before new head is exposed |
For a shop whose production depends on one machine, the full check is almost always the right choice. Our printhead replacement service guide describes what a professional head installation should include.
A safe head replacement sequence after an electrical failure
- Stop using the machine and record what happened, with photos of the nozzle check, connectors and board.
- Determine whether the failure was sudden or gradual and whether burning signs were present.
- Fix any ink leak and clean any contamination from connectors (technician).
- Replace head cables and adapter boards for the affected head.
- Have the board inspected and the firing channel tested.
- Repair or replace the board if the channel is faulty.
- Check power supply and earthing.
- Verify the new head: correct type and variant, undamaged connector, label voltage photographed.
- Install the new head with power off, inserting cables straight and fully.
- Enter the correct voltage and head type, then power on and test.
- Monitor nozzle checks closely for the first days of use.
Our burnt head board after printhead change guide covers the installation side of this sequence.
Monitoring after the new head is fitted
Even after careful checks, watch the new head closely during its first days:
- Print a nozzle check at start-up and after a few hours of printing each day.
- Compare density with the other head on multi-head machines.
- Feel for unusual heat near the carriage electronics (without touching live parts) or ask the technician to check temperatures.
- Note any new dropouts that do not respond to cleaning.
Early detection of a remaining fault can save the head. If something seems wrong, stop and investigate rather than pushing on with production.
Prevention: stopping the first failure
The best way to avoid the repeat-failure cycle is to prevent the first electrical failure. The main measures are:
- Keep ink away from connectors and fix leaks immediately. See how ink leaks damage carriage boards.
- Never plug or unplug head cables with power on.
- Insert cables straight and fully, in the correct orientation.
- Enter the correct head voltage values.
- Protect the machine with a suitable stabiliser or online UPS and good earthing.
- Keep the carriage electronics cool and clean.
- Avoid head strikes by setting correct head height and handling media properly.
Further reading: Repeat head failures call for proper root cause analysis rather than another replacement.
Key takeaways
- A head that fails electrically can damage the firing channel and cable, and a damaged channel can kill the next head.
- Sudden total failure, burning signs, burnt contacts and repeat failures on the same channel all indicate the electronics may be involved.
- Before fitting a new head, replace cables, inspect the board, test the firing channel, verify settings, fix leaks and check power.
- Never test a suspect head on a good board or a suspect board with a new head.
- The cost of checking is small compared with the cost of losing another head, which is usually not covered by warranty.
If you have lost a head and want to make sure the next one is safe, the Unified Engineering Dynamics team can help check the firing circuit, cables and settings before you fit a new printhead.
More in the fire board series
- What Is a Fire Board on an Eco-Solvent Printer?
- Fire Board vs Head Board vs Mainboard
- Fire Board Failure Signs
- Head Voltage Settings and Head Life
- Fire Board Compatibility for i3200, XP600 and DX5
- Fire Board Repair vs Replacement
- Power Fluctuation and Fire Board Damage
- Fire Board Cooling and Dust
Related: our head carriage board series starts with Eco-Solvent Head Carriage Board Explained, and covers head cable vs carriage board fault finding and the carriage board replacement checklist.
Related: our main board series covers main board functions and failure points, main board failure symptoms, the main board replacement checklist and how lightning, surges and earthing faults damage main boards.
For a system-wide view, see our complete guide to eco-solvent printer electronics, our step-by-step electronics fault isolation guide and the monthly electronics maintenance checklist.
Frequently Asked Questions
Can a bad fire board really destroy a new printhead?
Yes. A damaged firing channel can deliver excessive, distorted or unstable voltage that damages the head’s piezo elements or internal electronics, sometimes within minutes.
How do I know if my old head damaged the fire board?
Sudden total failure, burning smell, burnt cable contacts or connector damage suggest a short that may have affected the firing channel. A technician should inspect and test the channel before a new head is fitted.
Should I replace head cables when replacing a failed head?
Yes, especially after an electrical failure. Burnt or damaged cable contacts can carry a short into the new head and board.
Can I test my old head on another printer’s board?
Not without checking it first. If the head is shorted, it can damage the good board. Use proper test methods.
Will the head supplier replace a new head that failed because of the board?
Usually not. Damage from overvoltage, shorts, cables or ink in connectors is generally excluded from warranty.
What does it cost to check the fire board before fitting a new head?
Typically a technician visit and some small parts such as cables. This is far less than the price of a new head.